TX-L55WT50 SMODE, Instrukcje obsługi

[ Pobierz całość w formacie PDF ]
Technical Description
Specification of KEY for CI Plus, DTCP-IP, One-to-One, Widevine and Netflix
General information:
1. EEPROM (IC8902) for spare parts has the seed of KEY for each.
2. The final KEY data will be generated by PRO4 IC (IC8000) when SELF CHECK was done and are stored in both PRO4 IC
(IC8000) and EEPROM (IC8902).
All KEYs are not generated for all models.
The necessary KEY are only generated and stored depend on the feature of models.
Replacement of ICs:
When PRO4 IC (IC8000) is replaced, EEPROM (IC8902) should be also replaced with new one the same time.
When EEPROM (IC8902) is replaced, PRO4 IC (IC8000) is not necessary to be replaced the same time.
After the replacement of IC, SELF CHECK should be done to generate the final KEY data.
How to SELF CHECK: While pressing [VOLUME ( - )] button on the main unit, press the
STATUS
button on the remote
control for more than 3 seconds.
TV will be forced to the factory shipment setting after this SELF CHECK.
Models and Keys:
Keys
Model No.
One-to-One
(for USB Rec.)
CI PLUS
DTCP-IP
Widevine
Netflix
TX-L55WT50E
Yes
Yes
Yes
Yes
Yes
TX-L55WT50T
Yes
Yes
Yes
Yes
Yes
USB HDD Recording:
General information:
Digital TV programmes can be recorded in USB HDD.
A One-to-One key generated in A-board by SELF CHECK binds TV and USB-HDD for communication.
That key is only one key for them. If the key is difference, TV can not access USB-HDD.
Caution:
New key will be generated by following SELF CHECK and previous TV programmes recorded in USB HDD will not be
viewed.
SELF CHECK: While pressing [VOLUME ( - )] button on the main unit, press the
STATUS
button on the remote control
for more than 3 seconds
11
 Setting Inspection
Voltage Confirmation
A board
Description
Test point
Voltage
SUB1.1V
TP8100
1.10V - 1.22V
SUB 1.5 V
TP8101
1.435V - 1.585V
SUB1.8V
TP8700
1.7V – 1.9V
SUB3.3V
TP5400
3.17V – 3.43V
SUB5V
TP5420
4.80V - 5.25V
USB5V
TP5440
4.94V – 5.40V
FE1.2V
TP5780
1.14V – 1.26V
FE1.2V/2.5V
TP5720
2.375V – 2.625V
PNL12V
TP4004 (TP4005)
11.5V – 12.9V
Horizontal 17.0V - 19.0V
LNB_OUTPUT
TP6702
Vertical 12.5V – 14.0V
12
 Self Check
Self-check is used to automatically check the bus lines and hexadecimal code of the TV set. To enter Self-Check mode, keep
pressing the down
(-/v)
button on the TV set and press the
STATUS
button on the remote
control. To exit Self Check,
switch off the TV set at the power button.
TX-L55WT50E
55FHD Panasonic 2012LCD
Self Check Complete
SUM C15D
TUN O.K.
STBY O.K.
MEM1 O.K.
MEM2 O.K.
AVSW O.K.
LAN O.K.
ZWEI O.K.
SAT-TU O.K.
ID O.K.
ID2 O.K.
BT O.K.
WiFi O.K.
PEAKS-SOFT 1.619
PEAKS-EEP 01.06.0011
LSI-PACKAGE 0.016
LSI-RELEASE 1.14
STBY-SOFT 1.00.02
STBY-EEP 1.00.0015
STBY-ROMCORR 0.00.00
ZWEI-SOFT 09010011
MODEL ID 09
03012100
00040000
TX-L55WT50T
55FHD Panasonic 2012LCD
Self Check Complete
SUM C178
TUN O.K.
STBY O.K.
MEM1 O.K.
MEM2 O.K.
AVSW O.K.
LAN O.K.
ZWEI O.K.
SAT-TU O.K.
ID O.K.
ID2 O.K.
BT O.K.
WiFi O.K.
PEAKS-SOFT 1.619
PEAKS-EEP 01.06.0027
LSI-PACKAGE 0.016
LSI-RELEASE 1.14
STBY-SOFT 1.00.02
STBY-EEP 1.00.0015
STBY-ROMCORR 0.00.00
ZWEI-SOFT 09010011
MODEL ID 09
03042300
00040000
Display
Ref. No.
Description
P.C.B.
TUN
TU6702
TUNER
A-Board
STBY
IC8000
Peaks-PRO4
A-Board
MEM1
IC8900
NAND FLASH MEMORY
A-Board
MEM2
IC8902
EEPROM PEAKS PRO4
A-Board
AVSW
IC3001
AUDIO/VIDEO SWITCH
A-Board
LAN
IC8600
LAN CONTROLER
A-Board
ZWEI
TC-unit
TC-unit on panel
TC-unit
SAT-TU
TU6702
TUNER
A-Board
ID
IC8902
CI+, DTCP-IP, C2mod
A-Board
ID2
IC8902
WIDEVINE , NETLFLIX
A-Board
IC8458
N5HZZ0000113
USB HUB
BT DONGLE
A-Board
BT Dongle
BT
IC8458
N5HBZ0000067
USB HUB
WIFI DONGLE
A-Board
Wifi Dongle
WiFi
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
13
 Power LED blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
Blinking
times
Blinking timing
Contents
Check point
Once
4 sec
A BOARD
P BOARD
Light
1
BL_SOS
No Light
A BOARD
3
IROM SOS
A BOARD
7
SUB3.3V_SENSE_SOS
A BOARD
8
SOS
A BOARD
9
SOUND_SOS
10
ZWEI_SOS
TC-unit on panel
12
BE_SOS
A BOARD
13
EMERGENCY
A BOARD
14
Service Mode Function
MPU controls the functions switching for each IICs through IIC bus in this chassis. The following setting and adjustment can
be adjusted by remote control in Service Menu
How to enter SERVICE
While pressing
(-/v
) button on the TV unit, press on the remote control for 3 times within 2 seconds.
0
Note:
To exit from Service mode, press the exit button on remote control.
15
[ Pobierz całość w formacie PDF ]